ESP32-S3 Edge DTU Development | Obeita

This configuration is proposed for assessment. Confirm interfaces, components and performance for your specific project.

Bring serial devices, contact signals and a CAN interface onto one ESP32-S3 edge board. This 24 V design combines two RS485 channels, a TTL port, isolated inputs and relay outputs with Wi-Fi or 10/100 Ethernet, making it a practical starting point for a small machine data-and-control gateway.

Field interfaces beyond a serial converter

Two RS485 channels and one TTL channel serve serial equipment, while two PC817 optocoupler inputs read discrete states. Two HF46F-024-HS1 relays are driven by ULN2003 circuitry. The CAN transceiver adds a separate physical bus; CAN application protocol support must be included explicitly in firmware scope.

Networking and local configuration

The ESP32-S3-WROOM-1U provides Wi-Fi, and a CH390 SPI Ethernet controller provides the wired path. RS485/TTL-to-TCP forwarding is the base software direction. A USB command-line terminal can expose configuration settings during commissioning. Local processing, cloud payloads and additional control logic are extensions rather than implied functions of every connector.

24 V cabinet integration

SGM6232 converts the 24 V rail to 3.3 V. TVS components are included on RS485, CAN and power paths, but final immunity levels require product tests. Data connectors use a 3.81 mm pitch and power connectors use 5.08 mm. A printed enclosure and an added rail bracket can be adapted for cabinet mounting; relay coil voltage and enclosure clearances must remain consistent with the power design.

Proposed design configuration

These are configuration inputs for development; the final assembly, firmware and acceptance tests define the delivered specification.

Item Configuration
Main module ESP32-S3-WROOM-1U
Network controller CH390, 10/100 Ethernet; Wi-Fi
Serial buses 2 × RS485; 1 × TTL
CAN 1 × SIT65HVD232DR transceiver path
Discrete I/O 2 optocoupler inputs; 2 relay outputs
Supply design 24 V DC; SGM6232 conversion

Project questions

Can a 12 V relay replace the 24 V relay directly?

Not without reviewing coil supply, drive current and the output circuit. The base design uses a 24 V coil; changing it is a hardware revision.

Is CAN ready for any industrial protocol?

The transceiver provides the electrical interface. CAN identifiers, bit rate, frame decoding and any higher-level protocol still need a defined implementation.

Plan this project

Send the two RS485 device manuals, CAN protocol, input signal type and relay loads, together with the available cabinet supply.